MNE ENG
HOME PRODUCTS REFERENCES PARTNERS ABOUT US CONTACT
Products
Cables:
Installation cables | Power cables | Rubber Cables | Telecommunication Cables | Various conductors
Lighting | Lightning Equipment | Cabinets | Accessories | Columns | Transformer Stations | Transformers
P
The installation of insulated wire PVC
JUS N.C3.200
Nominal voltage: 450/750 V
Temperature range:
-20 ° C to +70 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
copper wire,
insulation of PVC.
Application: In dry locations, for permanent laying in tubes, which can be above or below the plaster and the insulation of the body.
Packing: In coils of 50 and 100 m
PPY
Installation wire insulated and sheathed PVC
JUS N.C3.220
Nominal voltage: 300/500 V
Temperature range:
-20 ° C to +70 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
copper wire,
insulation of PVC,
construction of non vulcanised rubber
sheath of PVC.
Application: In dry and damp locations for taking over and under the plaster. Taking is not allowed into the country, outdoors or in a concrete watering.
Packing: In coils of 50 and 100 m or 1,000 m drum
EN-PP00 PP00-A
Power cable insulated and sheathed PVC
JUS N.C5.220
Nominal voltage: 0,6 / 1kV
Temperature range:
-40 ° C to +70 ° C (operating)
+5 ° C to +70 ° C (in passing)
Construction:
conductor copper / aluminum rope
insulation of PVC,
construction of not vulcanized rubber,
sheath of PVC.
Usage: For power distribution in city networks, industrial plants, thermal and hydro plants. Take the cable channels, closed offices in the country with the application of additional protection.
Packaging: 500 and 1,000 m on wooden drums.
X00-O
Self-supporting cable bundle with supporting rope
JUS N.C5.250
Nominal voltage: 0,6 / 1 kV
Temperature range:
-20 ° C to +90 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
aluminum wire,
carrying element of the Al / Fe (61/10 mm2) or AlMg (71.5 mm2) rope,
XLPE insulation.
Usage: Applies to the overhead electric distribution networks for electricity to run household connections, the network of public lighting and industrial power distribution.
Packaging: 500 and 1,000 m on wooden drums.
XHE49-A - 6/10 kV i 12/20 kV
One power cable wire cross-linked polyethylene insulated and wrapped with PE-mass
DIN VDE 276-620
Nominal voltage: 6 / 10 kV
Temperature range:
-20 ° C to +90 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
aluminum wire rope
semiconductor layer around the conductor
insulation of XLPE
semiconductor layer around the insulation
conductive strip which can easily grow
electrical protection of copper wire
insulating tape which can easily grow
sheath of PE-mass
Use: For high-voltage power distribution in distribution networks, power plants, industrial plants and Substations.
Packaging: 500 and 1,000 m on wooden drums.
XHP48 XHP48-A
Triple-wire power cable that is insulated with cross-linked polyethylene and PVC-wrapped mass.
JUS N.C5.230
Nominal voltage: 6 / 10 kV
Temperature range:
-20 ° C to +90 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
conductor copper / aluminum rope
semiconductor layer around the conductor,
XLPE insulation,
semiconductor layer around the insulation,
electrical protection from copper tape around each vessel separately,
construction of PVC over the core cable,
sheath of PVC.
Use: For high-voltage power distribution in distribution networks, power plants, industrial plants and Substations.
Packaging: 500 and 1,000 m on wooden drums.
GN50 EpN50
Insulated cable and rubber sheathed
JUS N.C5.350
Nominal voltage: 450/750 V
Temperature range:
-20 ° C to +60 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
copper conductor class 5
Isolation of ethylene-propylene rubber,
mantle of Neoprene rubber.
Use: For connection of portable devices with high mechanical stress in dry and damp rooms, outdoors and in areas where there is no danger of explosion in underground mines with no methane exploitation in construction and agricultural installations. Can be used for permanent installations laying on plaster, in temporary buildings and barracks for housing.
Packing: In coils of 50 and 100 m of 500 drums and 1,000 m.
GG/J
Insulated wire with sheathed rubber.
JUS N.C3.502
Nominal voltage: 300/500 V
Temperature range:
-20 ° C to +60 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
copper conductor class 5
Isolation of ethylene-propylene rubber,
mantle of ethylene-propylene rubber.
Application: indoors, the connection of household appliances and light workshop of the device at high mechanical strain. Not intended for permanent use outdoors.
Packing: In coils of 50 and 100 m of 500 drums and 1,000 m.
Telecommunication TK 59
Telephone subscription-filled cables with foam skin insulation
and layered shell of polyethylene, group folded
Collection of regulations ZJPTT
Temperature range:
-20 ° C to +50 ° C (operating)
+5 ° C to +50 ° C (in passing)
Construction:
copper wire 0.4 mm, 0.6 mm and 0.8 mm,
insulation foam skin polyethylene,
four wires are wrapped in a four star,
cable core is formed as a group with a core group of 5 quads,
mass to charge fully meet core cable,
belt insulation of at least one paper tape,
screen of aluminum tape coated on both sides with a layer of copolymers,
sheath of polyethylene.
Use: Apply to the local network to feed the cable channels and directly taking the country.
J-Y(St)Y
Installation cable with insulated and sheathed PVC.
VDE 0815
Temperature range:
-20 ° C to +50 ° C (operating)
+5 ° C to +50 ° C (in passing)
Construction:
copper wire 0.6 mm and 0.8 mm,
insulation of PVC,
wires are twisted into pairs,
cable core is formed of concentric layers,
belt insulation of at least one plastic tape,
display of AL-polyester tape and tinned copper longitudinally mounted wire
Gray PVC jacket.
Usage: Install cable with PVC insulation and PVC jacket used to carry telephone and other electrical signals and are designed for permanent installation in and above the plaster in dry and indoor spaces.
Various conductors P/F
The installation of insulated wire PVC - fine wire.
JUS N.C3.202
Nominal voltage: 450/750 V
Temperature range:
-20 ° C to +70 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
copper wire,
insulation of PVC.
Application: In dry areas where flexibility is a particular need. For installation in buildings sit in the pipes that may be above or below the plaster.
Packing: In coils of 50 and 100 m.
P/J
Installation wire insulated PVC.
JUS N.C3.203
Nominal voltage: 1000 V
Temperature range:
-20 ° C to +70 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
copper wire,
insulation of PVC.
Use: In wet locations and outdoors in the insulating body (for the home introduced), and for passing on the machine tools and ships with adequate protection.
Packing: In coils of 50 and 100
P/L
Parallel flexible insulated wire insulated PVC.
JUS N.C3.300
Nominal voltage: 300 V
Temperature range:
-20 ° C to +70 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
copper wire tie,
wires placed in parallel in the same plane,
insulation of PVC.
Usage: To access the smaller portable non-thermal energy spent, such as table lamps, radios, table fans and more.
Packing: In coils of 50 and 100 m.
PP/J
Wire insulated and sheathed PVC
JUS N.C3.302
Nominal voltage: 300/500 V
Temperature range:
-20 ° C to +70 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
copper wire-tie,
insulation of PVC,
sheath of PVC.
Use: For connection of portable spent designed for medium heavy-duty in homes, business premises and the like. including wet areas such as. washing machines, vacuum cleaners, dust and cooling devices. Allowed to use the equipment for cooking and heating, provided that wire is not exposed to radiant heat
Packing: In coils of 50 and 100 m.
PP/L
Lightweight flexible wire insulated and sheathed PVC.
JUS N.C3.301
Nominal voltage: 300/300 V
Temperature range:
-20 ° C to +70 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
copper wire-tie,
insulation of PVC,
sheath of PVC.
Usage: To access the smaller portable spent the easier working conditions, such as portable lamps, fans, cooling devices, etc..
Packing: In coils of 50 and 100 m.
P
The installation of insulated wire PVC
JUS N.C3.200
Nominal voltage: 450/750 V
Temperature range:
-20 ° C to +70 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
copper wire,
insulation of PVC.
Application: In dry locations, for permanent laying in tubes, which can be above or below the plaster and the insulation of the body.
Packing: In coils of 50 and 100 m.
GG/J
Wire insulated and sheathed rubber.
JUS N.C3.502
Nominal voltage: 300/500 V
Temperature range:
-20 ° C to +60 ° C (operating)
0 ° C to +50 ° C (in passing)
Construction:
copper conductor class 5
Isolation of ethylene-propylene rubber,
mantle of ethylene-propylene rubber.
Application: indoors, the connection of household appliances and light workshop of the device at high mechanical strain. Not intended for permanent use outdoors.
Packing: In coils of 50 and 100 m of 500 drums and 1,000 m.
Waterproof bulb – slanting
It is used for street lighting and lighting of individual buildings. Bulb comes with protective glass and lens hood.
OG - bulb - flat
It is used for street lighting and lighting of individual buildings. Bulb comes with a lens hood and a protective glass.
Lens hood
Lens hood are made of aluminum sheet with a thickness of 1mm. Surfaces are protected by electrostatic painting.
Street bulbs for the columns with chokes 125 W
It is used for street lighting and lighting of individual buildings.
bulb comes with lens hood and protective glass.
EUROKRISTAL
It is used for lighting streets, parks, squares, courtyards, factory rounds and in all other places that need good lighting. Street lamp consists of: cast casing made of high quality aluminum alloy cast under pressure, the protector of polycarbonate (glass), diffuser (mirror) from dragged anodiranog high purity aluminum, vertical - horizontal supports, silicone seals.
Installation-removal lamp parts can be done without using tools from the top of the European IEC standards, with no possibility of falling the protector and other parts of it. The advantage of these lamps compared to other manufacturers is that, when it is time to replase bulbs, you shouldn't remove protector, because it may damage, then the use of street lamps cast FULS excluded the possibility of unpleasant light flashes while driving.
Hot galvanized tape
Description of development:
development by: PN-EN50164-2
filled material: Hot rolled steel
thickness of the coating: Z350, Z500 upon request
standard circles: from 25kg to 50kg
Delivery: unbound or on pallets
Bus for potential equalization
This clamp, suitable for connecting multiple wires with collective rails.
Cross pieces
They are made of steel sheet with a thickness of 2.5 mm, and are used for connection-continuation tape on the floor. Protected by galvanic zinc, and if customer want we also do and hot galvanization.
Clamp for pipe

Clamp is the tubular element with lightning installations used for fixing the lightning line of pipes of various pipes in buildings and other facilities. It's universal, it can be used for flat and round conductors.
Corrosion protection was carried out galvanizing zinc and according to the customer's request we also do hot galvanizing.
Support for the ducts with concrete cube
They are used for fixing the lightning line of buildings and other facilities. It's universal, it can be used for flat and round conductors. By order, we also make other types of support. .It is delivered without concrete cube.
Corrosion protection was carried out galvanizing zinc, and according to the customer's request we also do hot galvanizing.
Support for the lines with wood thread
They are used for fixing the lightning line of buildings and other facilities. It's universal, it can be used for flat and round conductors. By order, we also make other types of support.
Corrosion protection was carried out galvanizing zinc, and according to the customer's request we also do hot galvanizing.
Cabinets
Mensural distribution cabinets (for internal and external mounting)
Connecting cabinets
Metal and plastic cabinets for various purposes
Accessories
Wooden columns
Reinforced - concrete columns
Galvanised columns
Galvanized columns are steel columns that are dipped in melted zinc solution.
Steel gridy columns
Lighting columns
Compact prefabricated concrete substation KTS1 1x630 (1x1000) kVA, 10 (20) / 0,4 kV, KTS2 1x630 (1x1000) kVA, 10 (20) / 0,4 kV and KTS3 2x630 (2x1000) kVA, 10 (20) / 0, 4kV are designed as free standing half buried objects.
There are designed for installation: 10kV switching block (20) / 0,4 kV type Ring Unit, power transformers 630kVA or 1000 kVA and low voltage switchboard.
Compact concrete substations are assemblied type, made of prefabricated reinforced concrete elements of the mark MB 40: compact fundamental part of the walls and roof, witch enables fast and easy installation.
Doors and shutters are made of anodized aluminum.
The object makes a harmonious architectural complex and can be installed in any area, any location, and not to endanger the ambient environment..
Power transformers
Three-phase distribution transformers for voltage drives up to 36 kV, with an output of 50 to 630 KVA
0.72 kV power transformers
12-38 kv power transformers
Voltage transformers
Voltage transformers for indoor and outdoor use.
Insulators and stands
Voltage insulators
Conductive Insulators
Supporting insulators

Completed jobs
Look at institutions, agencies and companies with whom we have collaborated successfully.